IF-STIM Plus, coming soon...
- Dual channel (4-lead) all digital combination Interferential and Muscle Stim (EMS)
- 6 Preset & 8 Adjustable Programs: 4 IFT Sweep, 4 IFT Shift, 4 EMS, 1 Sequential IFT/EMS, and 1 Constant Frequency with Vector)
- Preset and programmable treatment timer
- Premodulated (2-electrode) and Quadra-polar (4-electrode) programs
- Easy set-up and use
- Microprocessor technology with push button controls
- Low-battery indicator
- Treatment Pause/Resume button
- Durable metal belt clip
- AC wall adapter or 9V battery power supply
- 1-year warranty
- Comes with 1 pkg of 4 reusable self-adhering electrodes, 1 set 43” pin lead wires, 1 each 9V alkaline battery, AC wall adapter, zippered carrying tote, and instruction manual
- Leadwire reorder # LW46SPLE
Channel Dual, isolated between channels
Amplitude Adjustable; 0-80 mA peak at 500 ohm load (±10%)
Output Voltage 35 V peak to peak on resistive load of 500 ohms
Waveform IFT: symmetrical square wave, EMS: symmetrical biphasic square wave
Pulse Width IFT: 125 µS, EMS: 300 µS
IFT Carrier Frequency 4000 Hz fixed, channel 1
IFT Adjustable Frequency 4001-4400 Hz, channel 2
Interference Frequency Adjustable, 1-440 Hz
EMS Pulse Rate 60 Hz fixed
Timer Programs 1-6: preset; program 7: 1-30 minutes
Programs
PRG: 1 IFT Low Sweep: 1-20 Hz (fixed), 12 sec sweep time, 4-elect, 20 min.
PRG: 2 IFT High Sweep: 100-250 Hz (fixed), 12 sec sweep time, 4-elect, 20 min.
PRG: 3 IFT Wide Sweep: 1-250 Hz (fixed), 24 sec sweep time, 4-elect, 20 min.
PRG: 4 IFT Dual Sweep: 60-160 Hz (fixed), 12 sec sweep time, 4-elect, 20 min.; 1-20 Hz (fixed), 12 sec sweep time, 4-elect, 20 min.
PRG: 5 EMS: Pulse Width: 300 µS, Rate: 60 Hz, On Time 6 sec, Off Time 3 sec, Ramp 2 sec, 2-elect, 20 min.
PRG: 6 IFT & EMS Sequential Combo
• 60-120 Hz IFT, 6 sec sweep time, Pre-modulated 2-elect, 20 min.
• 60 Hz EMS, On Time 6 sec, Off Time 3 sec, Ramp 2 sec, 2-elect, 20 min.
• 1-20 Hz IFT 12 sec sweep time, Pre-modulated 2-elect, 20 min.
PRG: 7.1-7.8 Custom IFT (10-160 Hz) and EMS (30, 60, 90, 120 Hz) modes, and selectable treatment timer
• 7.1 IFT Constant (selected frequency remains constant, with vector sweep)
• 7.2 IFT 1|1 Shift (selected frequency reduces to 50% for 1 sec., then increases to 150% for the next 1 sec.)
• 7.3 IFT 3|3 Shift (selected frequency reduces to 50% for 3 sec., then increases to 150% for the next 3 sec.)
• 7.4 IFT 6|6 Shift (selected frequency reduces to 50% for 6 sec., then increases to 150% for the next 6 sec.)
• 7.5 IFT 9|9 Shift (selected frequency reduces to 50% for 9 sec., then increases to 150% for the next 9 sec.)
• 7.6 EMS 6/6 (selected frequency 6 sec. ON, 6 sec. OFF, 2 sec. ramp)
• 7.7 EMS 6/12 (selected frequency, 6 sec. ON, 12 sec. OFF, 2 sec. ramp)
• 7.8 EMS 6/18 (selected frequency, 6 sec. ON, 18 sec. OFF, 2 sec. ramp)
Power Supply 9V battery or AC adapter
Size 6.35 x 13.97 x 2.54 cm
Weight 689.4 grams
|