 Medi-Stim, Inc.217 Industrial Court
 Wabasha, MN 55981
 Toll Free: 1-800-363-STIM
 Ph: (651) 565-2400
 Fax: (651) 565-2410
 sales@medi-stim.com
 
 
 | 
            
              
                
                  | TENS Units > Neuro-Care TENS |  
                  | 
    
  
  
 |  |  
                  | 
                      Dual channel (4-lead) digital TENS 
Five treatment modes (Normal, Burst, Modulated Rate, Modulated Width, Strength Duration)
Attractive high-tech design with metallic finish w/ LCD display
Hinged protective cap for intensity dials
Easy-to-use push-button controls
Locking battery/control panel
Durable metal wire belt clipTreatment timer 5-60 minutes, or ContinuousCompliance monitor records up to 999 hours and 59 minutes of use3-year warranty
Comes with 1 pkg of 4 reusable self-adhering electrodes, 1 set 43” pin lead wires, 1 each 9V heavy duty battery, carrying case, and instruction manual
Leadwire reorder # LW46SPLE
 
                      Channel: Dual, isolated between channels Amplitude: Adjustable, 0 - 90 mA; max output 90 mA 
                      (peak to peak) into 500 ohm each channelOutput Voltage: Adjustable, 0 - 45 V; max output 45V 
                      (peak to peak) into 500 ohm each channelWaveform: Asymmetrical biphasic square pulse Pulse Rate: Adjustable, 1 ~ 150 Hz, 1 Hz/step Pulse Width: Adjustable, 30 ~ 300 µS, 10 µS/step
                        Modes Five (Normal, Burst, Modulated Rate, Modulated Width, 
                        Strength Duration)
 Normal (N) Continuous output, pulse rate and pulse width are adjustable.
 Burst Mode (B) Burst rate adjustable, 0.5 ~ 5 Hz; Pulse width adjustable, 30 ~ 300 µS, Frequency fixed = 100 Hz
 Modulation (MR) Pulse rate is automatically varied in a cyclic pattern over an interval of nominally 10 seconds (in max 150 Hz). Pulse rate decreases linearly over a period of 5 seconds from the control setting value to a value which is 70% less, then increases linearly over a 5 seconds period to its original value. The cycle is then repeated.
 Modulated Width (MW) Pulse width is automatically varied in a cyclic pattern over an interval of nominally 10 seconds (in max 300 µS). Pulse width decreases linearly over a period of 5 seconds from the control setting value to a value which is 70% less, then increases linearly over a 5 seconds period to its original value. The cycle is then repeated.
 Strength Duration (SD) Pulse rate and pulse width are varied in a cyclic pattern over an interval of nominally 10 seconds. so the pulse width is always increasing while the pulse rate is decreasing and vice-versa. Pulse rate decreases linearly over a period of 5 seconds from the control setting value to a value which is 90% less (width equal to setting). Pulse width decreases linearly over a period of 3 seconds from the control setting value to a value which is 38% less (rate equal to setting). The cycle is then repeated. Pulse rate (from 1 ~ 150 Hz) and pulse width (from 30 ~ 300 µS) are fully adjustable.
 Timer: Adjustable, 5, 10, 20, 30, 40, 50, 60 minutes or Continuous
 Power Supply: One 9-volt battery
 Size: 10 x 6 x 2.1 cm
 Weight: 120 grams with battery
 |  |