 Medi-Stim, Inc.217 Industrial Court
 Wabasha, MN 55981
 Toll Free: 1-800-363-STIM
 Ph: (651) 565-2400
 Fax: (651) 565-2410
 sales@medi-stim.com
 
 
 | 
            
              
                
                  | TENS Units > Select-Care TENS |  
                  | 
  
 
                
               
                
  
                   
                                 
               |  
 |  
                  | 
                      Dual channel (4-lead) all digital TENS
Three treatment modes (Normal, Burst, Modulated Rate) + 9 preset programs 
Treatment timer (30, 60 minutes or Continuous for manual modes)
Power ON/OFF button for easy shut-off
Last setting recall & settings lock
Compliance monitor
Safety anti-slip plastic side guard strips 
3 year warranty
Comes with 1 pkg of 4 reusable self-adhering electrodes, 1 set 43” pin lead wires, 1 each 9V heavy duty battery, carrying case, and instruction manual
Leadwire reorder # LW46SPLE
 
                      Channel: Dual, isolated between channelsAmplitude: Adjustable, 0 - 80 mA peak to peak into 500 ohm loadOutput Voltage: Adjustable, 0 - 40V peak to peak into 500 ohm loadWaveform: Asymmetrical rectangular biphasicPulse Rate: Adjustable, 1 - 150 Hz, 1 Hz/stepPulse Width: Adjustable, 30 - 300 µS, 10 µS/stepModes: Normal, Burst, Pulse Rate Modulation, and Program Burst; Burst rate adjustable, 0.5 ~ 5 Hz Pulse width adjustable, 50 ~ 300 µS Frequency fixed at 100HzNormal - Constant output based on the setting value
 P.R. Modulation (-40%) - Pulse rate is automatically varied in a cyclic pattern over an interval of nominally 10 seconds. (in max 150Hz) Pulse rate decreases linearly over a period of 5 seconds from the control setting value to a value which is 40% less. Then increase linearly over a 5 seconds period to its original value. The cycle is then repeated.
Timer: 30, 60 minutes, or continuous (1-99 minutes can be set for presets)Power Supply: One 9-volt batterySize: 10.1 x 6.8 x 21.5 cmWeight: 155 grams with battery  
                      
                        | Program | Mode | Pulse Rate | Pulse Width | Timer |  
                        | P1 | Constant | 80 Hz | 180 μS | Continue |  
                        | P2 | Burst | 100 Hz(Burst Rate: 2 Hz)
 | 180 μS | Continue |  
                        | P3 | -70% PW Modulation | 80 Hz | 50-180 μS | Continue |  
                        | P4 | Mixed Frequency | 15 Hz in 3 sec/ 2 Hz in 3 sec
 | 180 μS | Continue |  
                        | P5 | Mixed Frequency | 80 Hz in 3 sec/ 2 Hz in 3 sec
 | 180 μS | Continue |  
                        | P6 | Constant | 10 Hz | 180 μS | Continue |  
                        | P7 | Constant | 80 Hz | 60 μS | Continue |  
                        | P8 | Constant | 80 Hz | 180 μS | 30 Minutes |  
                        | P9 | Burst | 100 Hz (Burst Rate: 2 Hz)
 | 180 μS | 30 Minutes |  |  |